Pre-test 743 Semi Anechoic Chamber

Anechoic Chamber Professional Maker

RF Anechoic Chamber (RF/EMC Chamber)

10m Semi Anechoic Chamber 

5m Semi Anechoic Chamber 

3m Semi Anechoic Chamber (966)

844 Shielded Room for RS Chamber

Pre-test 743 Semi Anechoic Chamber

Fully Anechoic Chamber

Open Area Test Site

Customized Anechoic Chamber

Frequency Range

EMI: 30M~6G(Hz)

Construction Dimensions reserved

7.5m(L)x4.5m(W)×3.5m(H)

Inner space

7.0m(L)x4.0m(W)×3.0m(H)

Raised floor

20cm(H)

Main Frame weight

6,000 kg ;230kg/㎡

Shielding Effectiveness Test(IEEE-299/ EN50147-1 ) 

30MHz≥100dB、450MHz≥100dB、

1GHz≥100dB、3GHz≥100dB、

6GHz≥100dB、 10GHz≥100dB

 

Controller

WP-Controller

Turn table

Diameter:1.2m ,Load:300kg ,0~360degree,control:optic fiber,

Operating Voltage: AC220V

Antenna

Height:2m , Stroke:1-2me,control:optic fiber, Operating Voltage: AC220V

 

Shielding door(manual) 2m(H) × 1.2m(W)

Power line filter:

#EUT : AC110V/220V 32Amps x1

#Lights  & Device: AC220V 32Amps x1

#AE:  AC220V 32Amps x1

Honeycomb:

#Size: 300 × 300 x 45mm(L*W*H)

Signal Access Panel

#N x 2 / SMA x 2 / BNC x 2

#Optic Fiber connector x 4

#Wave Guide  2inch x 1

Bi-Log Antenna

#Brand:Schwarzbeck

#Model:VULB 9168

#Frequency:25M~2GHz

CCTV system

#24” LCD Monitor x 2

#CCD camera x 1

#TV adapter box x1

Pre-Amplifier

#Brand:CLAVIIO

#Model:BDLNA-0001-272007

#Frequency:1k~1GHz

#Gain flatness:±0.75 dB

#Gain:27dB

Dr.E 2015 auxiliary EMI, you can observe, record, measure, analyze the required frequency range is also a single point or frequency, then after finishing the reporting system, show the complete test result.

Product

Warranty

Main part

10 years

Ferrite tile

10years

Shielding Door

3 year

Filter / control system

1 year

Lights and another device

1 year