844 Shielded Room for RS Chamber

Anechoic Chamber Professional Maker

RF Anechoic Chamber (RF/EMC Chamber)

10m Semi Anechoic Chamber 

5m Semi Anechoic Chamber 

3m Semi Anechoic Chamber (966)

844 Shielded Room for RS Chamber

Pre-test 743 Semi Anechoic Chamber

Fully Anechoic Chamber

Open Area Test Site

Customized Anechoic Chamber

RS 844 Semi Anechoic Chamber

No

Item

Description

QTY.

Unit

Major structure

1

PAN Type Modules

Outside dimension 8.0x 4.0 x 4.0m(apx.)

1

SET

The galvanized steel module is 2mm thick and product surface painting

Braid shielded and anti-slip screw

2

Steel Structure

H-Beam for five wall and insulating floor

1

SET

3

Ground System

Ground rod have a safe electrical system, near power filter

1

SET

4

Shielding Door

KT 1.2M*2M electric control swing type shielding door

1

SET

Can open manual inside/outside

Warning lamp

5

Air Vents

Waveguide air vents 300mm*300mm

6

PC

6

Power Line Filter

2x32A, Insertion Loss: >100dB, 14kHz~40GHz,

4

PC

7

Connector Panels

AP: N*2、SMA*2、50mm pipe *1

1

SET

CP:depend on design drawing

Absorber Materials

8

Anechoic Absorber Materials & Ferrite

Emerson & Cuming (E&C) EPP on four side wall and ceiling.

Floor : partially absorber

1

SET

9

White Cap

Make up panel (Cap type) – used non flammable material

1

SET

Control System

10

Antenna Tower

Bore sight antenna mast 1 ~ 4m lifting

1

SET

Resolution : 1cm

Lifting speed : 10 ~ 150mm/Sec

11

Turntable

Medium duty turntable–2m diameter with a 1,500 Kg weight capacity

1

SET

Rotation speed: 1-12 degree/sec

Positioning accuracy : ± 1 degree

Rotation range : +365 degree~-5 degree

Provide drain pipe for the washing machine

12

Controller

for Antenna tower and Turntable

1

SET

Can control IEEE-488.2 Bus antenna tower and turntable

Fiber connect control

13

Anechoic test table

180Lx120Wx80H cm, Tabletop made of PES

1

SET

CCTV System

14

CCTV System

32 X zoom camera and high definition record

One is monitoring chamber, the other is monitoring DUT

Exception handling and recording

1

SET

15

Projector

Non-interference monitor and rojector for debug

1

SET

Setting under floor

Monitor and rojector interference source is lower than chamber base

Illumication System

16

Illumication

Lifting LED will easy to maintenance (including controller)

6

SET

17

Drainage System

Drainage system for washing machine

1

SET

Shielding Room for test facility control of RS 844 Semi Anechoic Chamber

No

Item

Description

QTY.

Unit

1

PAN Type Modules

Outside dimension 3.0 x 3.0 x 3.0 m(Apx.)

1

SET

13cm raised floor, placeholder for drain pipe

The galvanized steel module is 2mm thick and product surface painting

Braid shielded and anti-slip screw

2

Ground System

Ground rod have a safe electrical system, near power filter

1

SET

3

Shielding Door

KT 1.2M*2M manual control swing type shielding door

1

SET

4

Air Vents

Waveguide air vents 300mm*300mm

4

PC

6

Power Line Filter

2x32A, Insertion Loss: >100dB, 14kHz~40GHz,

1

PC

7

Connector Panels

AP: N*2、SMA*2、50mm pipe *1

1

SET

CP:depend on design drawing

8

Anechoic Testing

Anechoic Testing follow EN50147-1(Latest)
10 KHz ≧ -60dB
100 KHz≧ -80 dB
1MHz ~ 18GHz ≧ -100dB

1

SET

9

Construction

According to the drawings and accommodation

1

SET

Shielding Room for Power Amplifier equipment of RS 844 Semi Anechoic Chamber

No

Item

Description

QTY.

Unit

1

PAN Type Modules

Outside dimension 2.0 x 3.0 x 3.0 m(Apx.)

1

SET

13cm raised floor, placeholder for drain pipe

The galvanized steel module is 2mm thick and product surface painting

Braid shielded and anti-slip screw

2

Ground System

Ground rod have a safe electrical system, near power filter

1

SET

3

Shielding Door

KT 1.2M*2M manual control swing type shielding door

1

SET

4

Air Vents

Waveguide air vents 300mm*300mm

4

PC

6

Power Line Filter

2x32A, Insertion Loss: >100dB, 14kHz~40GHz,

1

PC

7

Connector Panels

AP: N*2、SMA*2、50mm pipe *1

1

SET

CP:depend on design drawing

8

Anechoic Testing

Anechoic Testing follow EN50147-1(Latest)
10 KHz ≧ -60dB
100 KHz≧ -80 dB
1MHz ~ 18GHz ≧ -100dB

1

SET

9

Construction

According to the drawings and accommodation

1

SET

 
SHOW